Jennifer Livingston
Lead Product Designer | Specialist in Data-driven Insights & Complex Systems | Ex-Apple
Selected Projects
HVAC monitoring and alerts platform for commercial buildings
HOME
FACILITIES
ADMIN
Search facilities...
MC
ALD-3201
1739 N Milwaukee Ave, Chicago, IL 60647
58°F
Partly cloudy
62%
· H 64°F · L 52°F
Aldi — Wicker Park
HVAC
SITE DETAILS
Filters
All buildings
8 zones · 8 assets
CARDS
LIST
Zones
Sales Floor
79
°F
74
°F
SETPOINT
RTU-1 · Bryant 580J
Supply temp running 4°F above setpoint
Bakery
72
°F
69
°F
SETPOINT
RTU-4 · Bryant 580J
No alerts
Checkout
71
°F
70
°F
SETPOINT
RTU-3 · Bryant 580J
No alerts
Back Office
—
71
°F
SETPOINT
RTU-5 · Bryant 580J
RAC offline — no data for 42 min
Stockroom
—
No FTL device in this zone
RTU-2 · Bryant 580J
No alerts
Produce
70
°F
70
°F
SETPOINT
RTU-6 · Bryant 580J
No alerts
Break Room
73
°F
72
°F
SETPOINT
RTU-7 · Bryant 580J
No alerts
Front Entry
68
°F
69
°F
SETPOINT
RTU-8 · Bryant 580J
No alerts
Assets
RTU-1
WARNING
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Sales Floor
RTU-2
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Stockroom
RTU-3
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Checkout
RTU-4
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Bakery
RTU-5
WARNING
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Back Office
RTU-6
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Produce
RTU-7
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Break Room
RTU-8
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Front Entry
sense: triage() _solve.
FTL · FIELD TECHNOLOGIES LLC
·
OPS V1.0
Focus
Product Design & Research
Platform
Responsive web app
MC
58°F
Partly cloudy
62%
· H 64°F · L 52°F
Aldi — Wicker Park
HVAC
SITE DETAILS
Filters
All buildings
8 zones · 8 assets
Zones
Sales Floor
79
°F
74
°F
SETPOINT
RTU-1 · Bryant 580J
Supply temp running 4°F above setpoint
Bakery
72
°F
69
°F
SETPOINT
RTU-4 · Bryant 580J
No alerts
Checkout
71
°F
70
°F
SETPOINT
RTU-3 · Bryant 580J
No alerts
Back Office
—
71
°F
SETPOINT
RTU-5 · Bryant 580J
RAC offline — no data for 42 min
Stockroom
—
No FTL device in this zone
RTU-2 · Bryant 580J
No alerts
Produce
70
°F
70
°F
SETPOINT
RTU-6 · Bryant 580J
No alerts
Break Room
73
°F
72
°F
SETPOINT
RTU-7 · Bryant 580J
No alerts
Front Entry
68
°F
69
°F
SETPOINT
RTU-8 · Bryant 580J
No alerts
Assets
RTU-1
WARNING
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Sales Floor
RTU-2
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Stockroom
RTU-3
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Checkout
RTU-4
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Bakery
RTU-5
WARNING
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Back Office
RTU-6
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Produce
RTU-7
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Break Room
RTU-8
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Front Entry
sense: triage() _solve.
OPS V1.0
9:41
app.ftl.build
1
Mobile app for commissioning HVAC hardware in the field
JS
STEP 9 / 9
Asset connected & reporting
Take a screenshot of this report for your records — it's also saved to the asset record in FTL Cloud.
PROVISIONING REPORT
Jun 3, 2026 · 4:27 PM EST
CONNECTED
JOB INFO
Contractor
GE Mechanical
Technician
J. Smith
Customer
Wawa Inc.
Site
Wawa #321 — Philadelphia
Asset
RTU-3 Deli
Model
Carrier 48TCED14A2A6
Refrigerant
R-410A
Serial
FTL-RAC-00847
CONNECTION
Cloud status
Reporting
Sensors online
Temp ×4 · Current ×4
Wiring
R · C · G · Y1 confirmed
BACK
DONE
Installation Guide
Installation Guide
Device
RAC
STEP 1 / 8
Power off
Connect the existing thermostat wires to the LEFT terminal block.
Only needed if an existing thermostat will remain connected to the RAC.
Photograph the original wiring first. The RAC is a pass-through between the thermostat and the control board — match each wire to its label. R = + (24 V AC), C = − common. The terminal block pulls off if that makes wiring easier.

Connect thermostat wiring to the terminal on the LEFT.
BACK
NEXT STEP
9:41
provision.ftl.build
1
Focus
Product Design & Field Research
Platform
Mobile web app
JS
STEP 5 / 9
Wiring configuration
Confirm each terminal landed on the RAC. Tap to toggle confirmation.
R
24V Power
24VAC supply from RTU transformer
C
Common
Shared common / return
G
Fan
Fan relay command
Y1
Cool Stage 1
Compressor stage 1 command
Y2
Cool Stage 2
Not present on this unit
O/B
Reversing Valve
Not applicable — gas / electric heat
Once installed, the RAC will be in monitoring mode. Once a stat or terminal has been associated with this RAC, it will be in control mode.
BACK
CONTINUE
Installation Guide
9:41
provision.ftl.build
1
Multi-zone controller and wireless thermostat for commercial buildings

Aldi — Wicker Park
1739 N Milwaukee Ave, Chicago, IL 60647
58°F
Partly cloudy
62%
· H 64°F · L 52°F
Sales Floor
RTU-1
Live
History
Asset info
Run diagnostic
OCCUPANT REQUESTS · 1 OPEN
›
ALERT HISTORY
›
CRITICAL
Compressor not running
Commanded by drawing 0.4 A against its 14.2 A normal, and no cooling response (0.4 °F where stage 2 normally adds...
Silence
79
°F
48
%
Running
Cooling
Stage
1 of 2
Fan
On
SETPOINT
74
°F
CONTROL POINTS
Cool above
76°
Heat below
72°
Deadband
2°
MODE
Off
Auto
Fan
OVERRIDE LIMITS
On
Off
Lowest setpoint
62°
Highest setpoint
82°
Max duration
2 hr
Occupied
68°
74°
until 9:30 PM
Last 24 hours · CT
SCHEDULE
›
8:00 AM – 9:30 PM
12 AM
3 AM
6 AM
9 AM
12 PM
3 PM
6 PM
9 PM
12 AM
Space Temperature
Space
Cool above
Heat below
Last 24 hours · CT
59°
67°
75°
83°
12 AM
3 AM
6 AM
9 AM
12 PM
3 PM
6 PM
9 PM
12 AM
Airflow
3 probes · RTU-1
Return air
78.8°
Supply air
64.2°
Outdoor air
84.6°
ΔT now
14.6°
Peak cooling ΔT
9:40 AM
19.2°
Peak heating ΔT
6:10 AM
−38.4°
ΔT · last 24 hours CT
Current
Peak
RMS
4 clamps · RTU-1
Phase 1
6.6
A
Phase 2
6.8
A
Phase 3
7.0
A
Fan
3.9
A
Peak amps · last 24 hours CT
Sensors
3 devices
Stat
Control device
79°
›
Senstick 01
81°
›
Senstick 02
78°
›
Recent changes
VIEW More
›
Today 1:12 PM
Setpoint
72°
→
74°
Thermostat
Oct 26 4:05 PM
Schedule · Mon–Fri
8:00 AM – 9:00 PM
→
8:00 AM – 9:30 PM
Web app · Maria Chen
Oct 24 9:18 AM
Override max heating
80°
→
82°
Web app · Maria Chen
Danger!
Delete this zone
Once deleted, this zone and its associated records are removed. This action cannot be undone.
DELETE ZONE
sense: triage() _solve.
FTL · FIELD TECHNOLOGIES LLC · OPS V1.0
Focus
Hardware UX/UI
Platform
Touchscreen & e-paper devices
20%
79
°
F
45 min
74
°
AUTO ON
AUTO ON
Menu
Sales Floor · RTU-1
Truck on-route to service RTU-1
Supply temperature not meeting setpoint
Manual Override


Platform
B2C mobile-first PWA
Services
AI UX Design
Designing human-first AI for professional communication
FluentSphere


Platform
B2C mobile-first PWA
Services
UX/UI Consulting
Fostering sustainable habits with a strategic UX approach


Platform
B2C web app
Services
UX/UI Design
Enhancing clarity and consistency for a better user journey



Sales enablement app for customer conversations


Market research and assessment platform


Retail online and in-store assessment platform




Sales enablement app and admin publishing platform



Real estate transaction management platform



Mortgage and affordability calculators





Real estate and mortgage apps


Customer onboarding and program qualifications

Jennifer Livingston
Lead Product Designer | Specialist in Data-driven Insights & Complex Systems | Ex-Apple
Selected Projects
HVAC monitoring and alerts platform for commercial buildings
HOME
FACILITIES
ADMIN
Search facilities...
MC
ALD-3201
1739 N Milwaukee Ave, Chicago, IL 60647
58°F
Partly cloudy
62%
· H 64°F · L 52°F
Aldi — Wicker Park
HVAC
SITE DETAILS
Filters
All buildings
8 zones · 8 assets
CARDS
LIST
Zones
Sales Floor
79
°F
74
°F
SETPOINT
RTU-1 · Bryant 580J
Supply temp running 4°F above setpoint
Bakery
72
°F
69
°F
SETPOINT
RTU-4 · Bryant 580J
No alerts
Checkout
71
°F
70
°F
SETPOINT
RTU-3 · Bryant 580J
No alerts
Back Office
—
71
°F
SETPOINT
RTU-5 · Bryant 580J
RAC offline — no data for 42 min
Stockroom
—
No FTL device in this zone
RTU-2 · Bryant 580J
No alerts
Produce
70
°F
70
°F
SETPOINT
RTU-6 · Bryant 580J
No alerts
Break Room
73
°F
72
°F
SETPOINT
RTU-7 · Bryant 580J
No alerts
Front Entry
68
°F
69
°F
SETPOINT
RTU-8 · Bryant 580J
No alerts
Assets
RTU-1
WARNING
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Sales Floor
RTU-2
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Stockroom
RTU-3
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Checkout
RTU-4
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Bakery
RTU-5
WARNING
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Back Office
RTU-6
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Produce
RTU-7
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Break Room
RTU-8
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Front Entry
sense: triage() _solve.
FTL · FIELD TECHNOLOGIES LLC
·
OPS V1.0
Focus
Product Design & Research
Platform
Responsive web app
MC
58°F
Partly cloudy
62%
· H 64°F · L 52°F
Aldi — Wicker Park
HVAC
SITE DETAILS
Filters
All buildings
8 zones · 8 assets
Zones
Sales Floor
79
°F
74
°F
SETPOINT
RTU-1 · Bryant 580J
Supply temp running 4°F above setpoint
Bakery
72
°F
69
°F
SETPOINT
RTU-4 · Bryant 580J
No alerts
Checkout
71
°F
70
°F
SETPOINT
RTU-3 · Bryant 580J
No alerts
Back Office
—
71
°F
SETPOINT
RTU-5 · Bryant 580J
RAC offline — no data for 42 min
Stockroom
—
No FTL device in this zone
RTU-2 · Bryant 580J
No alerts
Produce
70
°F
70
°F
SETPOINT
RTU-6 · Bryant 580J
No alerts
Break Room
73
°F
72
°F
SETPOINT
RTU-7 · Bryant 580J
No alerts
Front Entry
68
°F
69
°F
SETPOINT
RTU-8 · Bryant 580J
No alerts
Assets
RTU-1
WARNING
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Sales Floor
RTU-2
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Stockroom
RTU-3
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Checkout
RTU-4
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Bakery
RTU-5
WARNING
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Back Office
RTU-6
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Produce
RTU-7
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Break Room
RTU-8
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Front Entry
sense: triage() _solve.
OPS V1.0
9:41
app.ftl.build
1
Mobile app for commissioning HVAC hardware in the field
JS
STEP 9 / 9
Asset connected & reporting
Take a screenshot of this report for your records — it's also saved to the asset record in FTL Cloud.
PROVISIONING REPORT
Jun 3, 2026 · 4:27 PM EST
CONNECTED
JOB INFO
Contractor
GE Mechanical
Technician
J. Smith
Customer
Wawa Inc.
Site
Wawa #321 — Philadelphia
Asset
RTU-3 Deli
Model
Carrier 48TCED14A2A6
Refrigerant
R-410A
Serial
FTL-RAC-00847
CONNECTION
Cloud status
Reporting
Sensors online
Temp ×4 · Current ×4
Wiring
R · C · G · Y1 confirmed
BACK
DONE
Installation Guide
Installation Guide
Device
RAC
STEP 1 / 8
Power off
Connect the existing thermostat wires to the LEFT terminal block.
Only needed if an existing thermostat will remain connected to the RAC.
Photograph the original wiring first. The RAC is a pass-through between the thermostat and the control board — match each wire to its label. R = + (24 V AC), C = − common. The terminal block pulls off if that makes wiring easier.

Connect thermostat wiring to the terminal on the LEFT.
BACK
NEXT STEP
9:41
provision.ftl.build
1
Focus
Product Design & Field Research
Platform
Mobile web app
JS
STEP 5 / 9
Wiring configuration
Confirm each terminal landed on the RAC. Tap to toggle confirmation.
R
24V Power
24VAC supply from RTU transformer
C
Common
Shared common / return
G
Fan
Fan relay command
Y1
Cool Stage 1
Compressor stage 1 command
Y2
Cool Stage 2
Not present on this unit
O/B
Reversing Valve
Not applicable — gas / electric heat
Once installed, the RAC will be in monitoring mode. Once a stat or terminal has been associated with this RAC, it will be in control mode.
BACK
CONTINUE
Installation Guide
9:41
provision.ftl.build
1
Multi-zone controller and wireless thermostat for commercial buildings

Aldi — Wicker Park
1739 N Milwaukee Ave, Chicago, IL 60647
58°F
Partly cloudy
62%
· H 64°F · L 52°F
Sales Floor
RTU-1
Live
History
Asset info
Run diagnostic
OCCUPANT REQUESTS · 1 OPEN
›
ALERT HISTORY
›
CRITICAL
Compressor not running
Commanded by drawing 0.4 A against its 14.2 A normal, and no cooling response (0.4 °F where stage 2 normally adds...
Silence
79
°F
48
%
Running
Cooling
Stage
1 of 2
Fan
On
SETPOINT
74
°F
CONTROL POINTS
Cool above
76°
Heat below
72°
Deadband
2°
MODE
Off
Auto
Fan
OVERRIDE LIMITS
On
Off
Lowest setpoint
62°
Highest setpoint
82°
Max duration
2 hr
Occupied
68°
74°
until 9:30 PM
Last 24 hours · CT
SCHEDULE
›
8:00 AM – 9:30 PM
12 AM
3 AM
6 AM
9 AM
12 PM
3 PM
6 PM
9 PM
12 AM
Space Temperature
Space
Cool above
Heat below
Last 24 hours · CT
59°
67°
75°
83°
12 AM
3 AM
6 AM
9 AM
12 PM
3 PM
6 PM
9 PM
12 AM
Airflow
3 probes · RTU-1
Return air
78.8°
Supply air
64.2°
Outdoor air
84.6°
ΔT now
14.6°
Peak cooling ΔT
9:40 AM
19.2°
Peak heating ΔT
6:10 AM
−38.4°
ΔT · last 24 hours CT
Current
Peak
RMS
4 clamps · RTU-1
Phase 1
6.6
A
Phase 2
6.8
A
Phase 3
7.0
A
Fan
3.9
A
Peak amps · last 24 hours CT
Sensors
3 devices
Stat
Control device
79°
›
Senstick 01
81°
›
Senstick 02
78°
›
Recent changes
VIEW More
›
Today 1:12 PM
Setpoint
72°
→
74°
Thermostat
Oct 26 4:05 PM
Schedule · Mon–Fri
8:00 AM – 9:00 PM
→
8:00 AM – 9:30 PM
Web app · Maria Chen
Oct 24 9:18 AM
Override max heating
80°
→
82°
Web app · Maria Chen
Danger!
Delete this zone
Once deleted, this zone and its associated records are removed. This action cannot be undone.
DELETE ZONE
sense: triage() _solve.
FTL · FIELD TECHNOLOGIES LLC · OPS V1.0
20%
79
°
F
45 min
74
°
AUTO ON
AUTO ON
Menu
Sales Floor · RTU-1
Truck on-route to service RTU-1
Supply temperature not meeting setpoint
Manual Override
Focus
Hardware UX/UI
Platform
Touchscreen & e-paper devices


Platform
B2C mobile-first PWA
Services
AI UX Design
Designing human-first AI for professional communication
FluentSphere


Platform
B2C mobile-first PWA
Services
UX/UI Consulting
Fostering sustainable habits with a strategic UX approach


Platform
B2C web app
Services
UX/UI Design
Enhancing clarity and consistency for a better user journey



Sales enablement app for customer conversations


Market research and assessment platform


Retail online and in-store assessment platform




Sales enablement app and admin publishing platform



Real estate transaction management platform



Mortgage and affordability calculators





Real estate and mortgage apps


Customer onboarding and program qualifications

Jennifer Livingston
Lead Product Designer | Specialist in Data-driven Insights & Complex Systems | Ex-Apple
Selected Projects
HVAC monitoring and alerts platform for commercial buildings
HOME
FACILITIES
ADMIN
Search facilities...
MC
ALD-3201
1739 N Milwaukee Ave, Chicago, IL 60647
58°F
Partly cloudy
62%
· H 64°F · L 52°F
Aldi — Wicker Park
HVAC
SITE DETAILS
Filters
All buildings
8 zones · 8 assets
CARDS
LIST
Zones
Sales Floor
79
°F
74
°F
SETPOINT
RTU-1 · Bryant 580J
Supply temp running 4°F above setpoint
Bakery
72
°F
69
°F
SETPOINT
RTU-4 · Bryant 580J
No alerts
Checkout
71
°F
70
°F
SETPOINT
RTU-3 · Bryant 580J
No alerts
Back Office
—
71
°F
SETPOINT
RTU-5 · Bryant 580J
RAC offline — no data for 42 min
Stockroom
—
No FTL device in this zone
RTU-2 · Bryant 580J
No alerts
Produce
70
°F
70
°F
SETPOINT
RTU-6 · Bryant 580J
No alerts
Break Room
73
°F
72
°F
SETPOINT
RTU-7 · Bryant 580J
No alerts
Front Entry
68
°F
69
°F
SETPOINT
RTU-8 · Bryant 580J
No alerts
Assets
RTU-1
WARNING
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Sales Floor
RTU-2
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Stockroom
RTU-3
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Checkout
RTU-4
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Bakery
RTU-5
WARNING
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Back Office
RTU-6
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Produce
RTU-7
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Break Room
RTU-8
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Front Entry
sense: triage() _solve.
FTL · FIELD TECHNOLOGIES LLC
·
OPS V1.0
Focus
Product Design & Research
Platform
Responsive web app
MC
58°F
Partly cloudy
62%
· H 64°F · L 52°F
Aldi — Wicker Park
HVAC
SITE DETAILS
Filters
All buildings
8 zones · 8 assets
Zones
Sales Floor
79
°F
74
°F
SETPOINT
RTU-1 · Bryant 580J
Supply temp running 4°F above setpoint
Bakery
72
°F
69
°F
SETPOINT
RTU-4 · Bryant 580J
No alerts
Checkout
71
°F
70
°F
SETPOINT
RTU-3 · Bryant 580J
No alerts
Back Office
—
71
°F
SETPOINT
RTU-5 · Bryant 580J
RAC offline — no data for 42 min
Stockroom
—
No FTL device in this zone
RTU-2 · Bryant 580J
No alerts
Produce
70
°F
70
°F
SETPOINT
RTU-6 · Bryant 580J
No alerts
Break Room
73
°F
72
°F
SETPOINT
RTU-7 · Bryant 580J
No alerts
Front Entry
68
°F
69
°F
SETPOINT
RTU-8 · Bryant 580J
No alerts
Assets
RTU-1
WARNING
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Sales Floor
RTU-2
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Stockroom
RTU-3
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Checkout
RTU-4
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Bakery
RTU-5
WARNING
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Back Office
RTU-6
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Produce
RTU-7
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Break Room
RTU-8
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Front Entry
sense: triage() _solve.
OPS V1.0
9:41
app.ftl.build
1
Mobile app for commissioning HVAC hardware in the field
JS
STEP 9 / 9
Asset connected & reporting
Take a screenshot of this report for your records — it's also saved to the asset record in FTL Cloud.
PROVISIONING REPORT
Jun 3, 2026 · 4:27 PM EST
CONNECTED
JOB INFO
Contractor
GE Mechanical
Technician
J. Smith
Customer
Wawa Inc.
Site
Wawa #321 — Philadelphia
Asset
RTU-3 Deli
Model
Carrier 48TCED14A2A6
Refrigerant
R-410A
Serial
FTL-RAC-00847
CONNECTION
Cloud status
Reporting
Sensors online
Temp ×4 · Current ×4
Wiring
R · C · G · Y1 confirmed
BACK
DONE
Installation Guide
Installation Guide
Device
RAC
STEP 1 / 8
Power off
Connect the existing thermostat wires to the LEFT terminal block.
Only needed if an existing thermostat will remain connected to the RAC.
Photograph the original wiring first. The RAC is a pass-through between the thermostat and the control board — match each wire to its label. R = + (24 V AC), C = − common. The terminal block pulls off if that makes wiring easier.

Connect thermostat wiring to the terminal on the LEFT.
BACK
NEXT STEP
9:41
provision.ftl.build
1
Focus
Product Design & Field Research
Platform
Mobile web app
JS
STEP 5 / 9
Wiring configuration
Confirm each terminal landed on the RAC. Tap to toggle confirmation.
R
24V Power
24VAC supply from RTU transformer
C
Common
Shared common / return
G
Fan
Fan relay command
Y1
Cool Stage 1
Compressor stage 1 command
Y2
Cool Stage 2
Not present on this unit
O/B
Reversing Valve
Not applicable — gas / electric heat
Once installed, the RAC will be in monitoring mode. Once a stat or terminal has been associated with this RAC, it will be in control mode.
BACK
CONTINUE
Installation Guide
9:41
provision.ftl.build
1
Multi-zone controller and wireless thermostat for commercial buildings

Aldi — Wicker Park
1739 N Milwaukee Ave, Chicago, IL 60647
58°F
Partly cloudy
62%
· H 64°F · L 52°F
Sales Floor
RTU-1
Live
History
Asset info
Run diagnostic
OCCUPANT REQUESTS · 1 OPEN
›
ALERT HISTORY
›
CRITICAL
Compressor not running
Commanded by drawing 0.4 A against its 14.2 A normal, and no cooling response (0.4 °F where stage 2 normally adds...
Silence
79
°F
48
%
Running
Cooling
Stage
1 of 2
Fan
On
SETPOINT
74
°F
CONTROL POINTS
Cool above
76°
Heat below
72°
Deadband
2°
MODE
Off
Auto
Fan
OVERRIDE LIMITS
On
Off
Lowest setpoint
62°
Highest setpoint
82°
Max duration
2 hr
Occupied
68°
74°
until 9:30 PM
Last 24 hours · CT
SCHEDULE
›
8:00 AM – 9:30 PM
12 AM
3 AM
6 AM
9 AM
12 PM
3 PM
6 PM
9 PM
12 AM
Space Temperature
Space
Cool above
Heat below
Last 24 hours · CT
59°
67°
75°
83°
12 AM
3 AM
6 AM
9 AM
12 PM
3 PM
6 PM
9 PM
12 AM
Airflow
3 probes · RTU-1
Return air
78.8°
Supply air
64.2°
Outdoor air
84.6°
ΔT now
14.6°
Peak cooling ΔT
9:40 AM
19.2°
Peak heating ΔT
6:10 AM
−38.4°
ΔT · last 24 hours CT
Current
Peak
RMS
4 clamps · RTU-1
Phase 1
6.6
A
Phase 2
6.8
A
Phase 3
7.0
A
Fan
3.9
A
Peak amps · last 24 hours CT
Sensors
3 devices
Stat
Control device
79°
›
Senstick 01
81°
›
Senstick 02
78°
›
Recent changes
VIEW More
›
Today 1:12 PM
Setpoint
72°
→
74°
Thermostat
Oct 26 4:05 PM
Schedule · Mon–Fri
8:00 AM – 9:00 PM
→
8:00 AM – 9:30 PM
Web app · Maria Chen
Oct 24 9:18 AM
Override max heating
80°
→
82°
Web app · Maria Chen
Danger!
Delete this zone
Once deleted, this zone and its associated records are removed. This action cannot be undone.
DELETE ZONE
sense: triage() _solve.
FTL · FIELD TECHNOLOGIES LLC · OPS V1.0
Focus
Hardware UX/UI
Platform
Touchscreen & e-paper devices
20%
79
°
F
45 min
74
°
AUTO ON
AUTO ON
Menu
Sales Floor · RTU-1
Truck on-route to service RTU-1
Supply temperature not meeting setpoint
Manual Override






Platform
B2C mobile-first PWA
Services
AI UX Design
Designing human-first AI for professional communication
FluentSphere


Platform
B2C mobile-first PWA
Services
UX/UI Consulting
Fostering sustainable habits with a strategic UX approach


Platform
B2C web app
Services
UX/UI Design
Enhancing clarity and consistency for a better user journey



Sales enablement app for customer conversations


Market research and assessment platform


Retail online and in-store assessment platform




Sales enablement app and admin publishing platform



Real estate transaction management platform



Mortgage and affordability calculators





Real estate and mortgage apps


Customer onboarding and program qualifications

Jennifer Livingston
Lead Product Designer | Specialist in Data-driven Insights & Complex Systems | Ex-Apple
Selected Projects
HVAC monitoring and alerts platform for commercial buildings
HOME
FACILITIES
ADMIN
Search facilities...
MC
ALD-3201
1739 N Milwaukee Ave, Chicago, IL 60647
58°F
Partly cloudy
62%
· H 64°F · L 52°F
Aldi — Wicker Park
HVAC
SITE DETAILS
Filters
All buildings
8 zones · 8 assets
CARDS
LIST
Zones
Sales Floor
79
°F
74
°F
SETPOINT
RTU-1 · Bryant 580J
Supply temp running 4°F above setpoint
Bakery
72
°F
69
°F
SETPOINT
RTU-4 · Bryant 580J
No alerts
Checkout
71
°F
70
°F
SETPOINT
RTU-3 · Bryant 580J
No alerts
Back Office
—
71
°F
SETPOINT
RTU-5 · Bryant 580J
RAC offline — no data for 42 min
Stockroom
—
No FTL device in this zone
RTU-2 · Bryant 580J
No alerts
Produce
70
°F
70
°F
SETPOINT
RTU-6 · Bryant 580J
No alerts
Break Room
73
°F
72
°F
SETPOINT
RTU-7 · Bryant 580J
No alerts
Front Entry
68
°F
69
°F
SETPOINT
RTU-8 · Bryant 580J
No alerts
Assets
RTU-1
WARNING
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Sales Floor
RTU-2
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Stockroom
RTU-3
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Checkout
RTU-4
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Bakery
RTU-5
WARNING
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Back Office
RTU-6
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Produce
RTU-7
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Break Room
RTU-8
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Front Entry
sense: triage() _solve.
FTL · FIELD TECHNOLOGIES LLC
·
OPS V1.0
Focus
Product Design & Research
Platform
Responsive web app
MC
58°F
Partly cloudy
62%
· H 64°F · L 52°F
Aldi — Wicker Park
HVAC
SITE DETAILS
Filters
All buildings
8 zones · 8 assets
Zones
Sales Floor
79
°F
74
°F
SETPOINT
RTU-1 · Bryant 580J
Supply temp running 4°F above setpoint
Bakery
72
°F
69
°F
SETPOINT
RTU-4 · Bryant 580J
No alerts
Checkout
71
°F
70
°F
SETPOINT
RTU-3 · Bryant 580J
No alerts
Back Office
—
71
°F
SETPOINT
RTU-5 · Bryant 580J
RAC offline — no data for 42 min
Stockroom
—
No FTL device in this zone
RTU-2 · Bryant 580J
No alerts
Produce
70
°F
70
°F
SETPOINT
RTU-6 · Bryant 580J
No alerts
Break Room
73
°F
72
°F
SETPOINT
RTU-7 · Bryant 580J
No alerts
Front Entry
68
°F
69
°F
SETPOINT
RTU-8 · Bryant 580J
No alerts
Assets
RTU-1
WARNING
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Sales Floor
RTU-2
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Stockroom
RTU-3
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Checkout
RTU-4
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Bakery
RTU-5
WARNING
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Back Office
RTU-6
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Produce
RTU-7
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Break Room
RTU-8
NO ALERTS
Type
Rooftop Unit (RTU)
Subtype
Packaged Single-Zone
MFR
Bryant
Model #
580J
Serial #
—
Parent entity
Zone · Front Entry
sense: triage() _solve.
OPS V1.0
9:41
app.ftl.build
1
Mobile app for commissioning HVAC hardware in the field
JS
STEP 9 / 9
Asset connected & reporting
Take a screenshot of this report for your records — it's also saved to the asset record in FTL Cloud.
PROVISIONING REPORT
Jun 3, 2026 · 4:27 PM EST
CONNECTED
JOB INFO
Contractor
GE Mechanical
Technician
J. Smith
Customer
Wawa Inc.
Site
Wawa #321 — Philadelphia
Asset
RTU-3 Deli
Model
Carrier 48TCED14A2A6
Refrigerant
R-410A
Serial
FTL-RAC-00847
CONNECTION
Cloud status
Reporting
Sensors online
Temp ×4 · Current ×4
Wiring
R · C · G · Y1 confirmed
BACK
DONE
Installation Guide
Installation Guide
Device
RAC
STEP 1 / 8
Power off
Connect the existing thermostat wires to the LEFT terminal block.
Only needed if an existing thermostat will remain connected to the RAC.
Photograph the original wiring first. The RAC is a pass-through between the thermostat and the control board — match each wire to its label. R = + (24 V AC), C = − common. The terminal block pulls off if that makes wiring easier.

Connect thermostat wiring to the terminal on the LEFT.
BACK
NEXT STEP
9:41
provision.ftl.build
1
Focus
Product Design & Field Research
Platform
Mobile web app
JS
STEP 5 / 9
Wiring configuration
Confirm each terminal landed on the RAC. Tap to toggle confirmation.
R
24V Power
24VAC supply from RTU transformer
C
Common
Shared common / return
G
Fan
Fan relay command
Y1
Cool Stage 1
Compressor stage 1 command
Y2
Cool Stage 2
Not present on this unit
O/B
Reversing Valve
Not applicable — gas / electric heat
Once installed, the RAC will be in monitoring mode. Once a stat or terminal has been associated with this RAC, it will be in control mode.
BACK
CONTINUE
Installation Guide
9:41
provision.ftl.build
1
Multi-zone controller and wireless thermostat for commercial buildings

Aldi — Wicker Park
1739 N Milwaukee Ave, Chicago, IL 60647
58°F
Partly cloudy
62%
· H 64°F · L 52°F
Sales Floor
RTU-1
Live
History
Asset info
Run diagnostic
OCCUPANT REQUESTS · 1 OPEN
›
ALERT HISTORY
›
CRITICAL
Compressor not running
Commanded by drawing 0.4 A against its 14.2 A normal, and no cooling response (0.4 °F where stage 2 normally adds...
Silence
79
°F
48
%
Running
Cooling
Stage
1 of 2
Fan
On
SETPOINT
74
°F
CONTROL POINTS
Cool above
76°
Heat below
72°
Deadband
2°
MODE
Off
Auto
Fan
OVERRIDE LIMITS
On
Off
Lowest setpoint
62°
Highest setpoint
82°
Max duration
2 hr
Occupied
68°
74°
until 9:30 PM
Last 24 hours · CT
SCHEDULE
›
8:00 AM – 9:30 PM
12 AM
3 AM
6 AM
9 AM
12 PM
3 PM
6 PM
9 PM
12 AM
Space Temperature
Space
Cool above
Heat below
Last 24 hours · CT
59°
67°
75°
83°
12 AM
3 AM
6 AM
9 AM
12 PM
3 PM
6 PM
9 PM
12 AM
Airflow
3 probes · RTU-1
Return air
78.8°
Supply air
64.2°
Outdoor air
84.6°
ΔT now
14.6°
Peak cooling ΔT
9:40 AM
19.2°
Peak heating ΔT
6:10 AM
−38.4°
ΔT · last 24 hours CT
Current
Peak
RMS
4 clamps · RTU-1
Phase 1
6.6
A
Phase 2
6.8
A
Phase 3
7.0
A
Fan
3.9
A
Peak amps · last 24 hours CT
Sensors
3 devices
Stat
Control device
79°
›
Senstick 01
81°
›
Senstick 02
78°
›
Recent changes
VIEW More
›
Today 1:12 PM
Setpoint
72°
→
74°
Thermostat
Oct 26 4:05 PM
Schedule · Mon–Fri
8:00 AM – 9:00 PM
→
8:00 AM – 9:30 PM
Web app · Maria Chen
Oct 24 9:18 AM
Override max heating
80°
→
82°
Web app · Maria Chen
Danger!
Delete this zone
Once deleted, this zone and its associated records are removed. This action cannot be undone.
DELETE ZONE
sense: triage() _solve.
FTL · FIELD TECHNOLOGIES LLC · OPS V1.0
Focus
Hardware UX/UI
Platform
Touchscreen & e-paper devices
20%
79
°
F
45 min
74
°
AUTO ON
AUTO ON
Menu
Sales Floor · RTU-1
Truck on-route to service RTU-1
Supply temperature not meeting setpoint
Manual Override






Platform
B2C mobile-first PWA
Services
AI UX Design
Designing human-first AI for professional communication
FluentSphere


Platform
B2C mobile-first PWA
Services
UX/UI Consulting
Fostering sustainable habits with a strategic UX approach


Platform
B2C web app
Services
UX/UI Design
Enhancing clarity and consistency for a better user journey



Sales enablement app for customer conversations


Market research and assessment platform


Retail online and in-store assessment platform




Sales enablement app and admin publishing platform



Real estate transaction management platform



Mortgage and affordability calculators





Real estate and mortgage apps


Customer onboarding and program qualifications